THINLINE II PROX READER -GREY ROHS PROX DFM

BRAND
HID
SES #
HID 5395CG100
MFG #
5395CG100
UPC
No UPC Set

Your Price

Usually ships between 3-7 business days

Providing performance and reliability, HID's attractive, unobtrusive ThinLine II proximity card reader is housed in a two-piece, weatherproof secure potted enclosure.
  • The size of most standard U.S. switch plates.
  • Available with Wiegand or Clock-and-Data interface.
  • Potted reader suitable for indoor or outdoor use.
  • Base part numbers: 5395 (Wiegand), 5398 (Clock-and-Data).
  • 18" (45 cm) wire pigtail standard; consult factory for 9' (2.7 m) pigtail available by special order.
  • Easily installed and maintained with the use of replaceable covers.
  • Available with a Wiegand or Clock-and-Data interface.
  • Provides high reliability, consistent read range and low power consumption.
  • Features include multicolor LED and internal control or host control of the LED and beeper.
  • Mounts directly on metal with minimal impact on the read range performance.
  • Aesthetic design available in two cover designs and four colors to match any décor.
  • Includes multilingual installation manual.
Typical maximum* read range
ProxCard II Card - up to 5.5" (14 cm)ISOProx II Card - up to 5" (12.7 cm)DuoProx II Card - up to 5" (12.7 cm)Smart ISO/DuoProx Cards - up to 5" (12.7 cm)Proximity & MIFARE Card - up to 5" (12.7 cm)ProxCard Plus Card - up to 1.5" (3.8 cm)ProxKey II Keyfob - up to 2" (5.1 cm)Microprox Tag - up to 3" (7.6 cm)*Depending on local installation conditions.
Dimensions
4.70" x 3.00" x 0.68" (11.9 x 7.6 x 1.7 cm)
Power Supply
5-16 VDCLinear power supplies are recommended.
Current Requirements
Average: 30 mA (5 VDC); 20 mA (12 VDC)Peak: 110 mA (5 VDC); 115 mA (12 VDC)
Operating Temperature
-22° to 150° F (-30° to 65° C)
Operating Humidity
0-95% relative humidity non-condensing
Weight
3.3 oz. (94 gm)
Cable Distance
Wiegand interface: 500 feet (150 m)Clock-and-data interface: 50 feet (15 m)Recommended cable is ALPHA 1295 (22 AWG) 5 conductor minimum stranded with overall shield or equivalent. Additional conductors may be required for LED or beeper control.
Certifications
Canada/UL 294 ListedFCC Certification, United States Canada CertificationEU and CB Scheme Electrical Safety (EN60950 and IEC60950 ITE Electrical Safety)Fifteen EU Countries under the R&TTE Directive (EN300 330 - SRD, and ETS 300 683 - EMC)CE MarkAustralia C-Tick, New ZealandTaiwan, China

Not a customer yet?

Register and discover the benefits SES delivers to your business today!