Remote Supervised 12VDC Power Supply for Fire Bus

BRAND
Napco Security Technologies
SES #
NAP GEMC12V2APSCF
MFG #
GEMC-12V2APS-CF
UPC
No UPC Set

Your Price

Usually ships between 3-7 business days

There are two versions of the GEMC-12V2APS: GEMC-12V2APS-CF (Commercial Fire) contains a transformer mounted inside the housing that requires a direct connection to a dedicated 120VAC circuit. The GEMC-12V2APS-R (Residential Fire/Burglary, Commercial Burglary) uses a plug-in 16.5VAC, 50VA class 2 transformer. Both versions use the GEMC12V2ABOARD UL Listed Subassembly. The GEMC12V2APS-CF or GEMC-12V2APS-R can be used as either: A UL Listed Accessory to a Gemini C-Series Combination Fire & Burglary Alarm control panel and GEMINI series control panels (GEM-X255, GEMP9600, GEM-P3200, Freedom F-64, GEM-P1664, GEM-P1632 and GEM-P816) or A UL Listed power supply for use with any listed Fire Alarm Control Panel (FACP), burglary control panel or access control system requiring an additional 12VDC auxiliary power Both versions use the GEMC-12V2ABOARD UL Listed subassembly, suitable for use as a replacement board.
  • When used with a Gemini C-Series control panel, the GEMC-12V2APS functions as an auxiliary 12V power supply with an integral EZM (Expansion Zone Module) used to send the status of the module (AC ON/OFF, BATTERY GOOD/TBL and TAMPER) to the control panel.
  • The GEMC-12V2APS is wired to the 4-wire fire bus of the C-Series control panel, and provides:
  • 3-Unsupervised active-low 2A outputs activated by AC FAIL, BATTERY TBL and MICRO TBL.
  • One supervised GEMC-Remote Bus interface
  • One normally-closed (N/C) housing tamper input, identified by trouble on dedicated integral EZM zone
  • 4 status LED's
  • ● Power supply contains integral battery charger capable of charging up to 1 pair of 12AH/12V sealed lead acid batteries
  • ● The system monitors for low battery, no battery, brownout* and monitors battery charging circuit voltage, identified by trouble on dedicated integral EZM zone
  • ● Solid State over-current protection
  • ● Integral housing tamper switch inputs to protect against the unauthorized opening of the housing cover and a rear tamper protecting removal of the housing from its mounting surface
  • ● The maximum number of GEMC-12V2APS's can be used on a Gemini C-Series control panel is determined by the number of available EZM's to monitor status. Each GEMC-12V2APS requires 3 zones (AC FAIL, BATT TBL and TBL) of the 4 EZM zones.
  • ● Cabinet included
  • ● Automatic switchover to stand-by battery when AC Fails
  • ● In Commercial installations, the power supplies are not to be employed as a power source for local audible alarm sounding devices or for off-premises alarm transmitter/communicators.